MACHINE_NO
stringclasses 48
values | ERROR_ID
int64 1
999
| ERROR_CODE
stringclasses 245
values | ERROR_DESC
stringlengths 14
179
| ERROR_CATEGORY1
stringclasses 11
values | SOLUTION
stringlengths 40
290
|
---|---|---|---|---|---|
KM-ASSYH1-03 | 1 | M7000 | M7000-Start detecting the presence of materials in the work area | Abnormal personnel operation | To solve the error M7000-Start detecting the presence of materials in the work area, the first step should be to check for any potential sources of contamination such as spills, debris, or dust particles. Once any materials |
KM-ASSYH1-03 | 17 | M7016 | M7016-EMO&&DOOR is open, please check the safety door or emergency stop X30 | Abnormal personnel operation | M7016-EMO&&DOOR is open - error message. |
KM-ASSYH1-03 | 18 | M7017 | M7017-Equipment model setting is abnormal, please set the model | Abnormal personnel operation | The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a |
KM-ASSYH1-03 | 19 | M7018 | M7018-Please press the reset button before starting the automatic process | Abnormal personnel operation | M7018 error usually occurs when the printer's automatic process fails to initiate properly. The solution is to press the reset button or perform a power cycle to restart the printer. |
KM-ASSYH1-03 | 20 | M7019 | M7019-The device has not returned to the origin, please execute the device to return to the origin first | Abnormal personnel operation | The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to |
KM-ASSYH1-03 | 21 | M7020 | M7020-There is product in the left pressing area when starting | Abnormal personnel operation | The solution for the error described as M7020-"There is product in the left pressing area when starting" is to move any obstructions or product out of the left pressing area of the printer before attempting to start the print job. |
KM-ASSYH1-03 | 22 | M7021 | M7021-There is a product in the middle pressing area during startup | Abnormal personnel operation | The M7021 error message indicates that there is a product in the middle pressing area during startup. To resolve the issue, remove the product from the area and check for any potential obstructions or debris that may be causing the issue. If |
KM-ASSYH1-03 | 23 | M7022 | M7022-There is product on the gripper of the right flip area during startup | Abnormal personnel operation | The solution for the error M7022-There is product on the gripper of the right flip area during startup is to remove any items from the gripper and clear the work area before starting the machine. |
KM-ASSYH1-03 | 24 | M7023 | M7023-There is a product on the left slide nozzle when starting, please take out the product and turn off the vacuum suction | Abnormal personnel operation | The solution for M7023 error is to remove the product from the left slide nozzle and turn off the vacuum suction. |
KM-ASSYH1-03 | 25 | M7024 | M7024-There is a product on the nozzle of the middle slide table when starting, please take out the product and turn off the vacuum suction | Abnormal personnel operation | To resolve this error, follow these steps: 1. Turn off the vacuum suction and prevent any further products from entering the middle slide table nozzle. 2. Manually remove any existing product from the nozzle. 3 |
KM-ASSYH1-03 | 26 | M7025 | M7025-There is a product on the right nozzle when starting, please take out the product and turn off the vacuum suction | Abnormal personnel operation | M7025 is an error message indicating that there is a product on the right nozzle while starting the vacuum cleaner. To resolve this, disconnect the hose from the suction inlet and press the button to turn off |
KM-ASSYH1-03 | 27 | M7026 | Kazam communication failed | Kazam exception | The solution for the "Kazam communication failed" error may vary depending on the specific cause of the issue. It could be due to an incorrect or outdated configuration, lack of permissions, or connectivity problems. Checking the Kazam server |
KM-ASSYH1-03 | 28 | M7027 | M7027-The machine model has been switched, please reset the belt width adjustment first | Abnormal personnel operation | This error typically occurs when you switch between different machine models and forget to reset the belt width adjustment. To resolve the error, follow these steps: identify the correct belt width for your new machine model, and adjust the belt width accordingly. If you |
KM-ASSYH1-03 | 29 | M7028 | M028-Please remove the TRAY plate from the conveyor belt first | Abnormal personnel operation | The solution to the error M028 is to follow the proper sequence of steps. This includes removing the TRAY plate from the conveyor belt before proceeding further. The system should be designed to ensure the correct order of steps are followed, |
KM-BFT | 1 | #00001 | Alarm after the plate is vacuumed three times | Machine cylinder abnormality | The solution to an error that occurs when the plate is vacuumed three times and results in an alarm could be to clean the filtration system or replace the filter. It could also be caused by a loose cable connection, so securing the c |
KM-BFT | 2 | #00002 | Emergency stop | Abnormal personnel operation | An emergency stop, also known as an emergency interrupt, is usually a physical or mechanical device in machines or devices that, when triggered, halts operation immediately to prevent further damage or injury. The solution for such a problem may vary depending on the specific |
KM-BFT | 3 | #00003 | Timeout alarm when the cylinder is waiting for the plate position to rise | Machine cylinder abnormality | The solution for the "Timeout alarm when the cylinder is waiting for the plate position to rise" error is to adjust the wait time or delay settings on the control system. Adjusting the timing settings can help reduce the likelihood of timeouts and |
KM-BFT | 4 | #00004 | Timeout alarm for lowering the cylinder of the waiting plate position | Machine cylinder abnormality | The solution for the described error involves resetting the brake controller to its default settings, disconnecting the brake controller from the wiring harness, and manually lowering the cylinder using the brake pedal. If the problem pers |
KM-BFT | 5 | #00005 | Scan barcode timeout alarm | Test exception | The solution for a Scan barcode timeout alarm typically involves increasing the time allowed for a scan to occur or using a faster scanner to read the barcode. Checking the equipment's battery and signal strength can also be helpful. If the |
KM-BFT | 6 | #00006 | Test timeout alarm | Test exception | The solution for a Test timeout alarm can vary depending on the cause. However, it is recommended to increase the timeout period in the test script, check network connectivity issues, and verify data input. If the issue persists, consulting technical support may |
KM-BFT | 7 | #00007 | Abnormal feeding level alarm | Sensor abnormality | The solution for an Abnormal Feeding Level Alarm depends on the specific device or system it is related to. Generally, it could indicate a malfunction or issue with the feeding level sensor or system. It is recommended to check the device manual |
KM-BFT | 8 | #00008 | Feeding blocked cylinder rise timeout alarm | Machine cylinder abnormality | The blocked cylinder rise timeout alarm can be resolved by unblocking the cylinder or rebooting the machine. If the issue persists, contacting the manufacturer for further assistance may be necessary. |
KM-BFT | 9 | #00009 | Feeding blocked cylinder lowering timeout alarm | Machine cylinder abnormality | The solution to a Feeding blocked cylinder lowering timeout alarm typically involves manually lowering the cylinder and bypassing the blockage or following the manufacturer's recommended maintenance procedure to clear the blockage. If the issue persists, contact |
KM-BFT | 10 | #00010 | Working position sensor abnormal alarm | Sensor abnormality | The solution for the Working position sensor abnormal alarm will depend on the specific cause of the issue. It may involve checking the sensor's connection, resetting the system, or replacing the sensor if needed. Consulting the sensor's manual or |
KM-BFT | 11 | #00011 | Working position blocks cylinder rising timeout alarm | Machine cylinder abnormality | The working position blocks cylinder rising timeout alarm means that the valve has failed to fully open or close within a set amount of time. The solution could involve either replacing the faulty valve or recalibrating the system. It's |
KM-BFT | 12 | #00012 | Working position blocks the descent of the cylinder and timeout alarm | Machine cylinder abnormality | To resolve the Working position blocks the descent of the cylinder and timeout alarm, you may have to check for any obstruction in the working position, inspect the cylinder and its components for damage, or adjust the control settings based on the specific C |
KM-BFT | 13 | #00013 | Jacking small cylinder rising timeout alarm | Machine cylinder abnormality | "Jacking small cylinder rising timeout alarm" is a problem that occurs when a small cylinder fails to respond to a signal from the jacker within the expected time frame, causing the jack to raise too quickly or not at all. To solve |
KM-BFT | 14 | #00014 | Timeout alarm for lowering of small jacking cylinder | Machine cylinder abnormality | The solution for the timeout alarm for lowering of a small jacking cylinder could involve adjusting the settings on the cylinder or the jack, checking for any blockages, or replacing the cylinder if it is damaged. It is also recommended |
KM-BFT | 15 | #00015 | Jacking large cylinder rise timeout alarm | Machine cylinder abnormality | The solution to a jacking large cylinder rise timeout alarm could involve resetting the cylinder height limit, checking for any obstacles that may be causing the jack to raise slowly, or updating the control system parameters to optimize performance. |
KM-BFT | 16 | #00016 | Jacking large cylinder lowering timeout alarm | Machine cylinder abnormality | The solution for the Jacking large cylinder lowering timeout alarm typically involves resetting the cylinder or implementing a workaround. It could also be due to a faulty valve or communication issue. Consult the owner's manual or contact a |
KM-BFT | 17 | #00017 | Reset failed alarm | Sensor abnormality | The "Reset failed alarm" error could be resolved by following these steps:
1. Press and hold the 1 key until the alarm sound stops.
2. Release the 1 key and press and hold the 2 key |
KM-BFT | 18 | #00018 | Product specification cylinder front position alarm | Machine cylinder abnormality | The Product specification cylinder front position alarm can typically be resolved by checking the position of the cylinder and making sure it is in the correct location. If the cylinder is misplaced or damaged, it may need to be replaced or adjusted |
KM-BFT | 19 | #00019 | Product standard cylinder rear position alarm | Machine cylinder abnormality | The product standard cylinder rear position alarm usually indicates that the rear wheel of the vehicle is not aligned correctly with the other wheels. To fix this issue, the wheels need to be adjusted so that they are all at the same angle. This can be |
KM-BFT | 20 | #00020 | Working position detects material during reset | Sensor abnormality | The solution for the error "Working position detects material during reset" is to disable the material detection function while the drill is powered on and the resetting process is in progress. This will prevent the drill from detecting material and trigger |
KM-BFT | 21 | #00021 | Reset the small jacking cylinder rising test position sensor and there is a product alarm | Sensor abnormality | The solution for the error "Reset the small jacking cylinder rising test position sensor and there is a product alarm" is as follows:
1. Identify the cause of the product alarm by inspecting the sensor and the jacking |
KM-BFT | 22 | #00022 | Abnormal output level alarm | Sensor abnormality | The solution to the "Abnormal output level alarm" error can vary depending on the specific error message and hardware or system being used. However, some possible steps to troubleshoot and resolve the issue include checking the settings or configurations of the affected device |
KM-BFT | 23 | #00023 | Discharge blocking cylinder rise timeout alarm | Machine cylinder abnormality | The solution for a discharge blocking cylinder rise timeout alarm typically involves resetting the alarm, checking the cylinder position sensor, and ensuring that the cylinder is not obstructed by debris or other items. |
KM-BFT | 24 | #00024 | Discharge blocking cylinder lowering timeout alarm | Machine cylinder abnormality | The solution for the error "Discharge blocking cylinder lowering timeout alarm" typically involves adjusting the speed and time settings of the cylinder's discharge, resetting the controller, or inspecting the cylinder for any blockages |
KM-BFT | 25 | #00027 | Check the alarm | Sensor abnormality | The solution for the error "Check the alarm" may vary depending on the context and device it appears on. It could mean to check the alarm or notification settings, reset the device, or contact customer support for further assistance. |
KM-BFT | 26 | #00028 | Alarm for product not in place | Sensor abnormality | This error usually occurs when a product is missing or in the wrong location in a warehouse or inventory management system. To resolve the issue, the product needs to be located and restocked, or the system needs to be updated with the correct product information. |
KM-BFT | 27 | #00029 | Receive permission to exit board timeout alarm | Machine communication abnormality | This error occurs due to a timeout while attempting to exit a board. To resolve this, ensure you have the correct permission to terminate the board process, or check and increase the timeout value. |
KM-BFT | 28 | #00030 | Discharge position timeout alarm | Sensor abnormality | The solution for a discharge position timeout alarm can vary depending on the cause and system. Generally, it can be addressed by clearing the alarm, resetting the system, or implementing adjustments to the alarm settings. If the issue persists, |
KM-BFT | 29 | #00031 | The sensor under the small lifting cylinder did not sense the product alarm | Sensor abnormality | There could be several possible reasons for this error, including a faulty sensor, incorrect product placement, or an issue with the lifting cylinder. To resolve the issue, it may be necessary to inspect the sensor and cylinder for damage, adjust product |
KM-BFT | 30 | #00032 | The machine is preparing to discharge material, and the material discharging level sensor alarms | Sensor abnormality | The solution to the error described involves adjusting the discharge level sensor to ensure that it is properly calibrated and functioning correctly. This may require aligning the sensor to match the discharge point or recalibrating the sensor in some cases |
KM-BFT | 31 | #00036 | Operation abnormality alarm | Abnormal personnel operation | The Operation abnormality alarm is an error code that suggests some unusual activity has been detected during normal operation. To resolve this issue, you can check the logs for error messages and review any system changes or updates made recently. If no specific issue is |
KM-BFT | 32 | #00037 | The product is stuck after being unboarded | Sensor abnormality | The solution for the error "The product is stuck after being unboarded" may involve resetting or restarting the device, checking for software updates, or contacting customer support for further assistance. |
KM-BFT | 33 | #00038 | Product feeding timeout | Sensor abnormality | 1 The solution for the error described as Product feeding timeout involves resetting the device and retrying the task, checking network connectivity and adjusting timeout settings. If the problem persists, contacting technical support may be necessary. |
KM-BFT | 34 | #00039 | Product discharging timeout | Sensor abnormality | The solution for a product discharging timeout error would be to reset or restart the product, check and clear any clogs or obstructions in the product's output, or consider contacting the product manufacturer for further assistance or support. |
KM-BFT | 999 | #ERROR | Other exceptions | Other exceptions | The solution for an "Other exceptions" error would depend on the context and specific cause of the exception. It could involve identifying the root cause of the error, debugging the code, and making necessary modifications or adjustments to fix the issue. Additionally |
KM-FPS | 1 | ERR_01 | If the feeding position is abnormal, please check X20 | Sensor abnormality | If the feeding position is abnormal, please check X20, is a message indicating that there is an issue with the feeding position sensor. This sensor is responsible for detecting the position of the equipment being fed and sending that information to the control |
KM-FPS | 2 | ERR_02 | If the material feeding at the test position is abnormal, please check X21 | Sensor abnormality | The solution for the error described as "If the material feeding at the test position is abnormal, please check X21" would be to investigate the issue with the X21 position and determine if it is causing the abnormal material feeding. |
KM-FPS | 3 | ERR_03 | The discharge level sensor is abnormal, please check X23 | Sensor abnormality | The solution for an abnormal discharge level sensor at X23 may involve checking the wiring connections, testing the sensor with a multimeter, calibrating the sensor, or replacing it if necessary. A qualified technician should be consulted |
KM-FPS | 4 | ERR_05 | The board is not flat, please check X24 | Sensor abnormality | The solution for the error "The board is not flat, please check X24" is likely to involve verifying that the board is securely and evenly attached to the stand or pedestal, and that the X24 section is properly |
KM-FPS | 5 | ERR_06 | The board is not flat, please check X25 | Sensor abnormality | The solution to the error "The board is not flat, please check X25" is to ensure that there are no raised or low points on the X25 board and that all components are flush with the surface. You may need to adjust |
KM-FPS | 6 | ERR_07 | The board is not flat, please check X26 | Sensor abnormality | To fix the issue, you need to check the X26 location on the board to make sure it's flat. Check if there are any bulges or bends in the board at that spot. If it's not flat, level |
KM-FPS | 7 | ERR_08 | The board is not flat, please check X27 | Sensor abnormality | The solution to the error "The board is not flat, please check X27" requires manual inspection of the electrical board to locate any bulges or bumps, causing the board to be uneven. If the component X27 appears anom |
KM-FPS | 8 | ERR_10 | Scan location detected product with no information | Test exception | The solution for the error "Scan location detected product with no information" is to perform a new scan on the product and ensure that it has the necessary barcode and product information. If the issue persists, update the scanner's firmware |
KM-FPS | 9 | ERR_11 | The upper computer sent an alarm signal | Test exception | The solution to the "The upper computer sent an alarm signal" error typically involves identifying and resolving the underlying issue that triggered the alarm, such as a hardware failure or software error, and then restoring normal system operation. |
KM-FPS | 10 | ERR_12 | The order chain is disordered | PLC logic exception | The solution for the error "The order chain is disordered" is to check the order flow and sequence of the order. Ensure that the order items are listed in the correct order, and that each item has proper information such as item name, quantity |
KM-FPS | 11 | ERR_13 | There are products inside the machine, please discharge them | Test exception | The solution for this error is to remove any products that may be inside the machine by following the manufacturer's instructions or contacting customer support for further assistance. Once the products are removed, the machine can be restarted and should function properly. It |
KM-FPS | 12 | ERR_14 | The abnormal internal product of the machine has been tested | Test exception | The solution to this error would depend on the specific machine and its internal product, but a possible solution might be to perform a diagnostic test or maintenance on the machine to identify and resolve any issues that may be causing the error. If the error persists |
KM-FPS | 13 | ERR_15 | The abnormal internal product of the machine is untested | Test exception | Based on the description of the error, you should first identify the machine and its internal product that is causing the abnormality. Once you have identified the problem, test the product to determine the root cause of the abnormality, and take necessary |
KM-FPS | 14 | ERR_16 | The machine is not in initial state, please reset it first | Abnormal personnel operation | The error message "The machine is not in initial state, please reset it first" typically occurs when a device, such as a computer or printer, is not functioning properly due to software issues or incorrect settings. The solution is to restart the device and |
KM-FPS | 15 | ERR_17 | The stopper cylinder entry front limit sensor is abnormal, please check X10 | Machine cylinder abnormality | The solution for the error message "The stopper cylinder entry front limit sensor is abnormal, please check X10" may be to check the sensor's connections and wiring, test the circuit, or replace the sensor if necessary. |
KM-FPS | 16 | ERR_18 | The stopper cylinder entry rear limit sensor is abnormal, please check X11 | Machine cylinder abnormality | The solution for the stopper cylinder entry rear limit sensor being abnormal and displaying "please check X11" is to verify the sensor's wiring and ensure that the X11 connector is properly connected. If the |
KM-FPS | 17 | ERR_19 | The front limit sensor of stopper cylinder 1 is abnormal, please check X12 | Machine cylinder abnormality | The front limit sensor of stopper cylinder 1 is abnormal and needs to be checked by inspecting cylinder X12. The issue may be related to the position of the sensor or its connection, and fixing it will resolve the error |
KM-FPS | 18 | ERR_20 | The rear limit sensor of stopper cylinder 1 is abnormal, please check X13 | Machine cylinder abnormality | The solution for the error described as the rear limit sensor of stopper cylinder 1 being abnormal is to perform a visual inspection of X13 and replace any damaged or faulty components that may be causing the issue. If the issue pers |
KM-FPS | 19 | ERR_21 | The front limit sensor of the stopper cylinder is abnormal, please check X16 | Machine cylinder abnormality | The front limit sensor of the stopper cylinder is faulty, and you need to check X16 for the solution. Ensure that the sensor is properly functioning and reset any necessary parameters to address the issue. Additionally, consider performing preventative maintenance |
KM-FPS | 20 | ERR_22 | The rear limit sensor of the stopper cylinder is abnormal, please check X17 | Machine cylinder abnormality | The solution for the rear limit sensor error may involve inspecting the stopper cylinder and X17 component for damage or malfunction, and possibly replacing the sensor. |
KM-FPS | 21 | ERR_23 | The front limit sensor of the large lift cylinder is abnormal, please check X30 | Machine cylinder abnormality | The solution to the error "The front limit sensor of the large lift cylinder is abnormal, please check X30" would involve examining the X30 sensor to determine if it is malfunctioning and causing the problem with the front |
KM-FPS | 22 | ERR_24 | The rear limit sensor of the large lift cylinder is abnormal, please check X31 | Machine cylinder abnormality | It's unclear from this information what X31 is and what the solution to the rear limit sensor issue is. The error message suggests that the sensor might be faulty or out of range, which could be causing the lift cylinder to |
KM-FPS | 23 | ERR_25 | Small lift cylinder front limit sensor is abnormal, please check X32 | Machine cylinder abnormality | The solution for the error "Small lift cylinder front limit sensor is abnormal, please check X32" may involve resetting or replacing the sensor, as well as addressing any underlying issue that may be causing the sensor to malfunction. It |
KM-FPS | 24 | ERR_26 | Small lift cylinder rear limit sensor is abnormal, please check X33 | Machine cylinder abnormality | The solution for the error "Small lift cylinder rear limit sensor is abnormal, please check X33" likely involves inspecting the X33 sensor for any damage or malfunction and replacing it if necessary. It may also involve adjusting |
KM-FPS | 25 | ERR_27 | Clamping cylinder front limit sensor is abnormal, please check X34 | Machine cylinder abnormality | The solution to the error "Clamping cylinder front limit sensor is abnormal, please check X34" may involve inspecting the X34 sensor for any issues or damage, cleaning or replacing it, and verifying its connections and |
KM-FPS | 26 | ERR_28 | The clamping cylinder rear limit sensor is abnormal, please check X35 | Machine cylinder abnormality | The clamping cylinder rear limit sensor may be incorrectly or malfunctioning. This can be caused by damage or improper installation. To resolve this issue, check the sensor for any signs of damage or misalignment and make any necessary |
KM-FPS | 999 | ERROR | Other exceptions | Other exceptions | The solution for an "Other exceptions" error would depend on the context and specific cause of the exception. It could involve identifying the root cause of the error, debugging the code, and making necessary modifications or adjustments to fix the issue. Additionally |
KM-ASSYH1-03 | 33 | M7032 | M7032-The feeding operation of the left working area conveyor belt has timed out, please check sensor X31 | Sensor abnormality | The solution for the error "M7032-The feeding operation of the left working area conveyor belt has timed out, please check sensor X31" is to investigate and repair or replace the faulty sensor X31, |
KM-ASSYH1-03 | 34 | M7033 | M7033-The discharging operation of the left working area conveyor belt has timed out, please check sensor X31 | Sensor abnormality | The M7033 error indicates that the discharging operation on the left working area conveyor belt has timed out, and it requires checking sensor X31 for any failure or malfunction. To resolve this issue, you can start |
KM-ASSYH1-04 | 178 | M7017 | M7017-Equipment model setting is abnormal, please set the model | Abnormal personnel operation | The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a |
KM-ASSYH1-04 | 179 | M7018 | M7018-Please press the reset button before starting the automatic process | Abnormal personnel operation | M7018 error usually occurs when the printer's automatic process fails to initiate properly. The solution is to press the reset button or perform a power cycle to restart the printer. |
KM-ASSYH1-04 | 185 | M7024 | Rear section-M7024-The conveyor belt product cannot return to the origin | Abnormal personnel operation | This error occurs when a conveyor belt product is removed from its conveyor belt and cannot be returned to its original location. The solution may involve resetting the belt, verifying that the product is properly aligned, or contacting the manufacturer for assistance |
KM-ASSYH1-05 | 131 | M7130 | Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first | Abnormal personnel operation | The solution to the error "Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first" is to physically remove the tray plate from the conveyor belt before attempting to process any items. |
KM-ASSYH1-05 | 161 | M7000 | The back-end PLC2-M7000-starts to detect that there is material in the work area, please confirm the status of the work area | Abnormal personnel operation | The solution for the error would be to visually inspect the work area to confirm if there is any material present. Once the area is clear, the PLC can be restarted, and the error should no longer occur. |
KM-ASSYH1-05 | 178 | M7017 | Backend PLC2-M7017-Equipment model setting is abnormal, please set the model | Abnormal personnel operation | The solution for the error "Backend PLC2-M7017-Equipment model setting is abnormal, please set the model" is to locate and reset the faulty equipment's Model Number on the Backend PLC |
KM-ASSYH1-05 | 180 | M7019 | Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first | Abnormal personnel operation | The solution to the error "Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first" involves performing an equipment return to the origin first. This ensures |
KM-ASSYH1-04 | 177 | M7016 | M7016-EMO&&DOOR is open, please check the safety door or emergency stop | Abnormal personnel operation | The M7016-EMO&&DOOR is open error signifies that the safety door or emergency stop is open, which is unsafe. The solution is to ensure that the safety door and emergency stop are properly closed before resuming work |
KM-ASSYH1-04 | 18 | M7017 | M7017-Equipment model setting is abnormal, please set the model | Abnormal personnel operation | The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a |
KM-ASSYH1-04 | 180 | M7019 | M7019-The device has not returned to the origin, please execute the device to return to the origin first | Abnormal personnel operation | The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to |
KM-ASSYH1-04 | 20 | M7019 | M7019-The device has not returned to the origin, please execute the device to return to the origin first | Abnormal personnel operation | The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to |
KM-ASSYH1-04 | 17 | M7016 | M7016-EMO&&DOOR is open, please check the safety door or emergency stop | Abnormal personnel operation | The M7016-EMO&&DOOR is open error signifies that the safety door or emergency stop is open, which is unsafe. The solution is to ensure that the safety door and emergency stop are properly closed before resuming work |
KM-ASSYH1-04 | 19 | M7018 | M7018-Please press the reset button before starting the automatic process | Abnormal personnel operation | M7018 error usually occurs when the printer's automatic process fails to initiate properly. The solution is to press the reset button or perform a power cycle to restart the printer. |
KM-ASSYH1-04 | 25 | M7024 | Front section-M7024-The conveyor belt product cannot return to the origin | Abnormal personnel operation | The solution for the Front section-M7024 error is to ensure the conveyor belt is properly programmed and configured to allow products to return to the origin. This can involve adjusting the control system settings, resetting the belt, |
KM-ASSYH1-05 | 1 | M7000 | The front-end PLC1-M7000-starts to detect that there is material in the work area, please confirm the status of the work area | Abnormal personnel operation | Unfortunately, without any context or additional information provided, it's impossible to provide a specific solution to the described error. However, it is recommended to check the documentation and user manuals for the PLC1-M7000, as |
KM-ASSYH1-05 | 18 | M7017 | Front stage PLC1-M7017-Equipment model setting is abnormal, please set the model | Abnormal personnel operation | The solution for the abnormal Front stage PLC1-M7017 equipment model setting is to set a new, valid model in the PLC. This can usually be done through the PLC's programming software or by physically reset |
KM-ASSYH1-05 | 20 | M7019 | Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first | Abnormal personnel operation | The solution to the error "Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first" is to first perform the equipment return to the origin before proceeding with |
KM-ASSYH1-05 | 17 | M7016 | If the front section PLC1-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17 | Abnormal personnel operation | The solution for this error is to check the safety door or emergency stop X17 when the front section PLC1-M7016-EMO&&DOOR is opened. |
KM-ASSYH1-05 | 177 | M7016 | When the rear section PLC2-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17 | Abnormal personnel operation | The solution for the error you described is to ensure that the safety door or emergency stop X17 is functioning properly and has not been triggered when the PLC2-M7016-EMO&&DOOR section is opened. This |
KM-ASSYH1-05 | 291 | M7130 | Rear section PLC2-M7130-Please remove the TRAY plate from the conveyor belt first | Abnormal personnel operation | One possible solution for this error is to physically remove the TRAY plate from the conveyor belt before the PLC2-M7130 can be accessed. This should prevent any interference or damage to the belt caused by the plate's |
KM-ASSYH1-05 | 19 | M7018 | Front stage PLC1-M7018-Please press the reset button before starting the automatic process | Abnormal personnel operation | The solution for the Front stage PLC1-M7018 error described as "Please press the reset button before starting the automatic process" is as follows: Press the reset button before starting the automatic process. This process should restart and run |
KM-ASSYH1-05 | 179 | M7018 | Backend PLC2-M7018-Please press the reset button before starting the automatic process | Abnormal personnel operation | The solution for the error "Backend PLC2-M7018-Please press the reset button before starting the automatic process" is to press the reset button for the PLC2-M7018 device to restart the automatic |